Atlassian uses cookies to improve your browsing experience, perform analytics and research, and conduct advertising. Accept all cookies to indicate that you agree to our use of cookies on your device.
Atlassian uses cookies to improve your browsing experience, perform analytics and research, and conduct advertising. Accept all cookies to indicate that you agree to our use of cookies on your device. Atlassian cookies and tracking notice, (opens new window)
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Samples of Accepted document types:
Australian Recognised Trade Certificate
Certificate of Completion of Apprenticeship
Certificate III
Samples of Accepted Course Titles / Coding:
Welder, First Class (Boilermaking)
Sheet Metal (First Class)
Engineering Fabrication
Must be an Australian or New Zealand (ANZCO) issued qualification - international qualifications outside of this are not accepted
Black and white or colour acceptable
Must be clearly scanned and legible
Issue Date = Date of completion
Expiry Date = No expiry date to be entered
Welder.-.Coded
Trade Certificate III Engineering - Fabrication or Boilermaker/Welding Apprenticeship AND a Welder Performance Qualification Record or Welder Certificate (WQT) as per AWS D1.1 or ASME Section IX)
OR
INDUSTRY SKILLED - Traceable experience as a CODED WELDER for at least 3 years (verified by fully completed SITE AUTHORISATION – RELEVANT EXPERIENCE EVIDENCE supported with written evidence - resume and referee, responsibility of the employer) PLUS MUST HAVE Tested and certified to ASME Section IX, coded welders (including boiler tube welders) are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor, also must be experienced in boiler tube welding – see example ie ASME Section IX EXAMPLE
INDUSTRY SKILLED BUSINESS RULE -see below
BOTH 1 & 2 below ARE MANDATED REQUIREMENTS of the role and need to be uploaded into AVETTA as one document for this role:
A copy of the required Site Authorisation – Relevant Experience Evidence Form can be downloaded here
The supplier company will be required to reach out to their site contact directly, providing the above form (with contractor to complete section completed) + evidence of at least 3 years relevant experience for their review. The authorised Yarwun site contact will then provide a signed copy of the Rio Tinto Site Authorisation Form back to the supplier company. The supplier company should upload a copy of the completed form WITH all supporting evidence for this requirement and submit for Avetta review who will assess the documentation against the following points: Applicants name to be shown on documentation Applicants name must match (However shortened versions such as 'Chris' for Christopher can be accepted) The site authorisation form approvers name, sign and date fields must be completed for each of the following: Contract Owner, CMT Superintendent Result must show: Evidence Accepted At least one additional supporting evidence page outside of the site authorisation form is included within the uploaded file.
PLUS
MUST HAVE tested and certified to ASME Section IX. Coded welders are tested and then re-validated 6 monthly by a certified Cert. 10welding supervisor
BOTH 1 & 2 MUST BE UPLOADED IN AS ONE CONTINUOUS DOCUMENT.
NOTE: INDUSTRY SKILLED WELDER CODED ROLE WILL EXPIRE AFTER 6 MONTHS OF COMPLETION OF ASME IX TEST IF NOT RENEWED.
ASME Issue Date to be recorded : The latest date of sign-off in the client approval table of the form Expiry Date: 6 months from issue date
Relevant experience example:
ASME EXAMPLE:
Welder.–.Boiler Tube
Trade Certificate III Engineering - Fabrication or Boilermaker/Welding Apprenticeship AND a Welder Performance QualificationRecord or Welder Certificate (WQT) as per AWS D1.1 or ASME Section IX)
OR
INDUSTRY SKILLED - Traceable experience as a CODED WELDER for at least 3 years (verified by fully completed SITE AUTHORISATION – RELEVANT EXPERIENCE EVIDENCE supported with written evidence - resume and referee, responsibility of the employer) PLUS MUST HAVE Tested and certified to ASME Section IX, coded welders (including boiler tube welders) are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor, also must be experienced in boiler tube welding – see example ie ASME Section IX EXAMPLE
INDUSTRY SKILLED BUSINESS RULE -see below
BOTH 1 & 2 below ARE MANDATED REQUIREMENTS of the role and need to be uploaded into AVETTA as one document for this role:
A copy of the required Site Authorisation – Relevant Experience Evidence Form can be downloaded here
The supplier company will be required to reach out to their site contact directly providing the above form (with contractor to complete section completed) + evidence of at least 3 years relevant experience for their review. The authorised Yarwun site contact will then provide a signed copy of the Rio Tinto Site Authorisation Form back to the supplier company. The supplier company should upload a copy of the completed form WITH all supporting evidence for this requirement and submit for Avetta review who will assess the documentation against the following points: Applicants name to be shown on documentation Applicants name must match (However shortened versions such as 'Chris' for Christopher can be accepted) The site authorisation form approvers name, sign and date fields must be completed for each of the following: Contract Owner, CMT Superintendent Result must show: Evidence Accepted At least one additional supporting evidence page outside of the site authorisation form is included within the uploaded file.
PLUS
MUST HAVE tested and certified to ASME Section IX. Coded welders are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor
BOTH 1 & 2 MUST BE UPLOADED IN AS ONE CONTINUOUS DOCUMENT.
NOTE: INDUSTRY SKILLED WELDER CODED ROLE WILL EXPIRE AFTER 6 MONTHS OF COMPLETION OF ASME IX TEST IF NOT RENEWED.
NOTE: Competency Welder/Boilermaker.-.Pipe weld test completed 6mths - also requires the above test evidence
ASME Issue Date to be recorded : The latest date of sign-off in the client approval table of the form Expiry Date: 6 months from issue date
Relevant experience example:
ASME EXAMPLE:
Welder.-.Coded IRATA L1
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
IRATA level 1 accreditation
PLUS
Trade Certificate III Engineering - Fabrication or Boilermaker/Welding Apprenticeship AND a Welder Performance Qualification
Record or Welder Certificate (WQT) as per AWS D1.1 or ASME Section IX)
OR Industry Skilled (Below)
INDUSTRY SKILLED -Traceable experience as a CODED WELDER for at least 3 years (verified by written evidence - resume and referee)
PLUS MUST HAVE Tested and certified to ASME IX. Coded welders are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor.
Issue Date = Date of completion
Expiry Date = 6 months from issue date
IRATA Example
Relevant experience example:
ASME EXAMPLE:
Welder.-.Coded IRATA L2
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
IRATA level 2 accreditation
PLUS
Trade Certificate III Engineering - Fabrication or Boilermaker/Welding Apprenticeship AND a Welder Performance Qualification
Record or Welder Certificate (WQT) as per AWS D1.1 or ASME Section IX)
OR Industry Skilled (Below)
INDUSTRY SKILLED -Traceable experience as a CODED WELDER for at least 3 years (verified by written evidence - resume and referee)
PLUS MUST HAVE Tested and certified to ASME IX. Coded welders are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor.
Issue Date = Date of completion
Expiry Date = 6 months from issue date
IRATA Example
Relevant experience example:
ASME EXAMPLE:
Welder.-.Coded IRATA L3
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
IRATA level 3 accreditation
PLUS
Trade Certificate III Engineering - Fabrication or Boilermaker/Welding Apprenticeship AND a Welder Performance Qualification
Record or Welder Certificate (WQT) as per AWS D1.1 or ASME Section IX)
OR Industry Skilled (Below)
INDUSTRY SKILLED -Traceable experience as a CODED WELDER for at least 3 years (verified by written evidence - resume and referee)
PLUS MUST HAVE Tested and certified to ASME IX. Coded welders are tested and then re-validated 6 monthly by a certified Cert. 10 welding supervisor.
Issue Date = Date of completion
Expiry Date = 6 months from issue date
IRATA Example
Relevant experience example:
ASME EXAMPLE:
Welder.Certificate.Aluminothermic-TLIW0006 – Heat and cut materials using oxy-LPG Equipment For the rail industry
Applicant's name on the document must match the name in the system however shortened versions such as 'Chris' for 'Christopher' are acceptable.
Evidence will be a certificate showing completion of:
TLIW0006 – Heat and cut materials using oxy-LPG For the rail industry
Issue Date = Date of completion
Welder.Certificate.Aluminothermic- TLIW3015 – Weld Rail Using Aluminothermic Welding Processes
Applicant's name on the document must match the name in the system however shortened versions such as 'Chris' for 'Christopher' are acceptable.
Evidence will be a certificate showing completion of:
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Issue Date = Date of completion
Expiry Date = No expiry date to be entered
Site.-.NDT; AINDT or PCN Accreditation Level 1
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Evidence will show recognition of Non Destructive Testing (also referred to as ISO 9712) with 'Level 1' being explicitly nominated.
Evidence must be issued by either AINDT, BINDT or PCN
Issue Date = As shown on the document
Expiry Date = As shown on the document
Site.-.NDT; AINDT or PCN Accreditation Level 2
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Evidence will show recognition of Non Destructive Testing (also referred to as ISO 9712) with 'Level 2' being explicitly nominated.
Evidence must be issued by either AINDT, BINDT or PCN
Issue Date = As shown on the document
Expiry Date = As shown on the document
Site.-.NDT; AINDT or PCN Accreditation Level 3
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Evidence will show recognition of Non Destructive Testing (also referred to as ISO 9712) with 'Level 3' being explicitly nominated.
Evidence must be issued by either AINDT, BINDT or PCN
Issue Date = As shown on the document
Expiry Date = As shown on the document
Site.-.Level 2 Phased Array Ultrasonic testing OR Time Flight Diffraction
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Evidence will show recognition of Level 2 - Phased Array Ultrasonic testing OR Time Flight Diffraction
Evidence must be issued by either AINDT, BINDT or PCN
Issue Date = As shown on the document
Site.-.Level 3 Phased Array Ultrasonic testing OR Time Flight Diffraction
Applicants name on the document must match name in the system (however shortened versions such as 'Chris' for 'Christopher' are acceptable)
Evidence will show recognition of Level 3 - Phased Array Ultrasonic testing OR Time Flight Diffraction
Evidence must be issued by either AINDT, BINDT or PCN
Issue Date = As shown on the document
Competency Name
Competency Requirements
Upload Requirements
Examples
Competency Name
Competency Requirements
Upload Requirements
Examples
Welder.-.RTAY Welding General - THEORY; 31415698
First and last name must match applicant's name in Onsite
Shortened versions of first names are accepted, such as: "Chris" instead of "Christopher" "Wil" instead of "William"
Shortened versions of last names are accepted, such as: "Herrera" instead of "Herrera Trujillo" "Mohd" instead of "Raza Hasan Mohd"
The following evidence can be accepted:
RTAY Recognition of Prior Competency
Rio Tinto Record of Completion
Theory Assessment or Site Authorisation All assessment pages within upload Matching competency name and code (if with checkbox, this should be completed) Applicant's signature and signed date Assessor's complete name Must show that the person is competent and authorised to operate
NOTE:
If Site Authorisation, the RCC Assessment or CTO Assessment section must be completed
If Theory Assessment, when RCC is completed, the authorised leader is required to verify with a signature that the applicant is authorised to operate
The learning and development section of the form does not need to be completed