Electrical.Statement of Attainment.EEHA Installation, Maintenance and Inspection

  • Evidence can be provided if the worker has previously completed the training

  • Evidence must show correct full name (Shortened versions such as 'Chris' for Christopher can be accepted)

  • Evidence must show completion date

  • RTO Name, National Provider Code/ RTO number & Logo to be displayed on evidence

  • Issue date must be listed on document

  • Certificate number must also be listed on document

  • Certificate or card is accepted

  • Certificate or card must be one of the two examples provided:

    • Must be a Statement of Attainment that list the following Units of Competency (UoC):

      • UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment

      • UEEHA0020 Conduct detailed inspection of electrical installations for hazardous areas

      • UEEHA0022 Determine the explosion-protection requirements to meet a specified classified hazardous area

      • UEEHA0025 Install explosion-protected equipment and associated apparatus and wiring systems

      • UEEHA0026 Maintain equipment associated with hazardous areas

      • UEEHA0029 Plan electrical installations for hazardous areas or UEEHA0027 Manage continuous supervision inspection of electrical installations for hazardous areas

      • UEEHA0038 Conduct visual and close inspection of electrical installations for hazardous areas

    • Can also accept Certificate IV in Hazardous areas- Electrical and must include the following UoC as minimum requirements:

      • UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment

      • UEEHA0020 Conduct detailed inspection of electrical installations for hazardous areas

      • UEEHA0022 Determine the explosion-protection requirements to meet a specified classified hazardous area

      • UEEHA0025 Install explosion-protected equipment and associated apparatus and wiring systems

      • UEEHA0026 Maintain equipment associated with hazardous areas

      • UEEHA0029 Plan electrical installations for hazardous areas

      • UEEHA0038 Conduct visual and close inspection of electrical installations for hazardous areas

      • UEECD0010 Compile and produce an energy sector detailed report

      • UEECD0024 Implement and monitor energy sector WHS policies and procedures.

      • UEECD0027 Participate in development and follow a personal competency development plan

      • UEEE0015 Implement and monitor energy sector environmental and sustainable policies and procedures.

Issue Date – Record issue date as shown on the document

Expiry Date3 years from completion date

 

Electrical.Statement of Attainment.High Voltage Switching

Expiry Date: 3 years from issue date 

 

Competency Name

Competency Requirements

Upload Requirements

Example

Competency Name

Competency Requirements

Upload Requirements

Example

Electrical.Licence.Unrestricted Electrical Worker Licence

Expiry Date: As listed on licence

Electrical.License. Electrician’s Licence VIC

Electrical.Licence.Electrical Workers Registration South Australia

Electrical.Licence.Electrical Technician’s Licence Tasmania

Electrical.Licence.Electrical ‘A’ Grade electrical works ‘All electrical Works’ WA

Electrical.Licence. Electrical Workers Licence NT

Electrical.Licence.Electrical Practicing Licence for registered electrician NZ

Electrical.Licence. Electrical Qualified Supervisor. Electrical NSW

Electrical.Licence.Electrical Contractor Licence

Expiry Date: As listed on licence

Electrical.Licence.Restricted Electrical Work Licence

  • Name on Licence must match the person registered (shortened version such as ‘Chris’ for Christopher can be accepted)

  • Must be issued by relevant state authority

  • Licence accepted from all Australian States.

  • Must be current

  • Must list all or any one of the following restricted works:

    • Refrigeration and air-conditioning equipment, any one or all the below restrictions:

      • Occupational Health and Safety

      • Disconnect and reconnect fixed wired equipment

      • Locate and rectify faults in 250v

      • Locate and rectify faults in 1000v

      • Attach flexible cord and plug for 250v

      • Attach flexible cord and plug for 1000v

    • Instrumentation/process control devices

    • Composite equipment limited to industrial equipment

    • Cathodic protection equipment excluding hazardous areas

    • Electronic equipment limited to 250VAC (Plug-in only)

Issue Date: Record issue date as shown on the document

Expiry Date:  5 years from date of issue/refresh.

 

Electrical.Licence.Electrical Jointer

  • Name on Licence must match the person registered (Shortened versions such as 'Chris' for Chirstopher can be accepted)

  • Must be issued by relevant state authority

  • Must be current

  • Must list Electrical Jointer

  • Colour copy or black and white accepted

Expiry Date: As listed on licence