Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Current »

DocumentDocument RequirementsUpload RequirementsExamples
Monthly Inspection
  • Inspection record to be stored with plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection must be at least 1 month from the previous monthly inspection
  • No non-compliances
  • Issue Date = Date of inspection
  • Expiry Date = 1 month from inspection date

Quarterly Inspection
  • Inspection record to be stored with plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection must be at least 3 months from the previous quarterly inspection
  • No non-compliances
  • Issue Date = Date of inspection
  • Expiry Date = 3 months from inspection date

Annual Inspection
  • Inspection record to be stored with plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection must be at least 1 year from the date the plant was first commissioned/registered/re-registered (whichever was first)
  • No non-compliances
  • Issue Date = Date of inspection
  • Expiry Date = 12 months from inspection date

6 Year Major Inspection
  • Inspection record to be stored with plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection must be at least 6 years from the date the plant was first commissioned/registered/re-registered (whichever was first)
  • No non-compliances
  • Issue Date = As listed on the recertification
  • Expiry Date = 6 years from recertification date

10 Year Major Inspection
  • Inspection record to be stored with plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection must be at least 10 years from the date the plant was first commissioned/registered/re-registered (whichever was first)
  • No non-compliances
  • Cranes not to be older than 20 years
  • Issue Date = As listed on the recertification
  • Expiry Date = 10 years from recertification date

Crane Safe Green Sticker Inspection
  • Crane Safe Sticker to be located on plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be CraneSafe certificate
  • Owner name on certificate to match the company owning the plant item
  • Duration as per expiry on certificate
  • Black and white or colour (green) acceptable
  • Only front of certificate needs to be shown when certificate is uploaded.
  • Issue Date = As listed on the certificate
  • Expiry Date = As listed on the certificate

Pile Safe Green Sticker Inspection
  • Pile Safe Sticker to be located on plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must be Pile Safe certificate
  • Owner name on certificate to match the company owning the plant item
  • Black and white or colour acceptable
  • Only front of certificate needs to be shown when certificate is uploaded
  • Issue Date = As listed on the certificate
  • Expiry Date = As listed on the certificate

DocumentDocument RequirementsUpload RequirementsExamples
General Condition Photo
  • Image must clearly show the plant that is being registered in the system
  • Issue Date = None
  • Expiry Date = None

DocumentDocument RequirementsUpload RequirementsExamples
Maintenance Report
  • Maintenance report to be stored with the plant item
  • Plant details to be displayed on evidence (Type and Model)
  • Must list required maintenance intervals
  • Must list the plant's hours and/or kilometres
  • Must show the last three completed services
  • Report signed and dated by licenced mechanic or relevant qualification
  • Issue Date = As per date on report
  • Expiry Date = 12 months from issue date

Monthly Pipeline Thickness Report
  • Reports need to be stored with the pump
  • Must be recorded in a readable and understandable format that ties in with plant item
  • Single wall pipes to have thickness tests available
  • Twin wall pipes to have volumes recorded with upper limits detailed as they cannot be thickness tested
  • Issue Date = As per report
  • Expiry Date = None

DocumentDocument RequirementsUpload RequirementsExamples
Current Lifting Equipment Register
  • Lifting Equipment Register must be available for plant items performing lifting tasks
  • Plant details to be displayed on evidence (Type and Model)
  • Company issuing report must be accredited by either:
  • Company name on certificate to match the company owning the
  • Black and white or colour acceptable
  • Only front of certificate needs to be shown when certificate is uploaded
  • Issue Date = As per document
  • Expiry Date = 12 months from issue date

Lift/Tie Down Certification
  • Certification record to be stored with plant item
  • Asset details to be displayed on evidence (Type and Model)
  • Must be completed by a competent person:
    • Professional engineer
    • NDT technician
    • Qualified tradesman
  • Date of inspection at least 1 year from the date the asset was first commissioned/registered/re-registered (whichever was first)
  • Issue Date = As per certification
  • Expiry Date = 12 months from issue date

Load Charts
  • Load charts to be stored with plant item
  • Asset details to be displayed on evidence (Type and Model)
  • Must list lifting point locations and their rated capacity
  • If applicable, must list boom configuration and the maximum load that can be lifted for each lifting point and boom configuration
  • If applicable, must list stabiliser requirements
  • If applicable, must list deductions for attachments (e.g. a bucket or quick-hitch devices)
  • Issue Date = None
  • Expiry Date = None

Quick Hitch Compliance Documentation
  • Hitch certification details to be stored with plant item
  • Must be uploaded for excavators fitted with Quick Hitches
  • Plant details to be displayed on evidence (Type and Model)
  • Evidence needs to verify fully auto hitch
  • Issue Date = As per document
  • Expiry Date = None

Risk Assessment
  • Risk Assessment doesn’t need to be updated unless the plant has been modified for another use
  • Plant Risk Assessment to be conducted via manufacturer/supplier of plant or specialist risk assessment company
  • Issue Date = As per assessment
  • Expiry Date = None

Page Version: 7

Note: This Document is not version controlled when printed.